{"product_id":"mimolite-z-wave-low-voltage-input-output-module","title":"Z-Wave MIMOlite Low Voltage Input\/Output Module","description":"\u003cp\u003eProvides one analog of digital signal input and one relay output (isolated dry contacts, NO-COM-NC) and is capable of Z-Wave™ input\/output control.\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Shop for Z-Wave Water Shutoff Valve Package Deals at inovativehomesys.com\" href=\"http:\/\/innovativehomesys.com\/collections\/e-hvac\/products\/z-wave-water-shutoff-valve-package-deal-1\" target=\"_blank\"\u003e\u003cstrong\u003eCheck out our Z-Wave™ Water Shutoff Valve Package Deal!\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConvert  digital or analog voltage input and\/or a Z-Wave™ RF message input to a dry contact relay output and\/or a Z-Wave™ RF message output.\u003c\/p\u003e\n\u003cp\u003eMIMOlite comes in a plastic enclosure for indoor use only.\u003c\/p\u003e\n\u003cp\u003e* Connect one wired devices to Signal input and make them wireless.\u003cbr\u003e * Connect them functionally to your Home Security panel OR to your Z-Wave™ home automation network\u003cbr\u003e * Connect high or low up to 16V digital signals\u003cbr\u003e * Connect pulse reading devices\u003cbr\u003e * Connect up to 16V analog signals\u003c\/p\u003e\n\u003cp\u003eThe MIMOlite module provides one input and one relay output (isolated dry contacts, NO-COM-NC) and is capable of Z-Wave™ input\/output\/control. The system includes a program switch for Z-Wave™ inclusion\/exclusion and an LED for various status indications.  We recommend checking with the manufacturer of your Z-Wave™ home security panel or home automation controller to verify support for MIMOlite input and\/or output.\u003c\/p\u003e\n\u003cp\u003eInput SIG1 is an analog input, internally pulled-up to the MIMOlite supply voltage. The system allows trigger conditions to be set based on the input voltage being inside or outside a user-defined range (configured via Z-Wave™). This provides great flexibility for capturing events in a wide variety of applications. The trigger status of the input can be read via Z-Wave™ and\/or can be automatically sent to a configured node, typically the Controller. In addition, a count of the trigger events that have occurred for each input channel are internally recorded (and stored in the 'pulse count') and are available to be read via Z-Wave™. The current triggered\/un-triggered status can also be read via Z-Wave™. The SIG1 input can be associated with up to two other Z-Wave™ devices, such that an associated device will automatically turn on (or off) based on the occurrence of a trigger event. Finally, the analog input channels can be configured so they periodically send the analog input level (not just trigger status) to up to two other associated nodes.\u003c\/p\u003e\n\u003cp\u003eThe output relay is, typically, commanded via Z-Wave™ commands. In addition, the user can configure the input SIG1 trigger condition to be mapped to the output relay. For example, Relay 1 can be automatically turned on based on Input SIG1 being triggered.  The relay activation can be set via a jumper or via Z-Wave™ for either momentary or latched operation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePower: 9-16 V DC from a power supply @~ 300mA capability\u003c\/p\u003e\n\u003cp\u003eFrequency Range: 908.4MHz (US); 868.4MHz (EU)\u003c\/p\u003e\n\u003cp\u003eDistance Range: Max 100ft line of sight in unobstructed environment\u003c\/p\u003e\n\u003cp\u003eEnclosure Size (L x W x D): 3 3\/8\" (85mm) x 2 1\/2\" (64mm) x 1 1\/4\" (30mm)\u003c\/p\u003e\n\u003cp\u003eWeight: 4 oz (100 gram)\u003c\/p\u003e\n\u003cp\u003eOperating Temperature: -10⁰C (14F) to +70⁰C (158F)\u003c\/p\u003e\n\u003cp\u003eInput Signal 1 (SIG1): Digital or Analog Input 0 to 16V DC or 16 Hz Max for pulse counting (minimum 32 ms high or low time). The trigger levels and hysteresis can be set via the Configuration Command Class for the two endpoints.\u003c\/p\u003e\n\u003cp\u003eInput Signal Impedance Input impedance for SIG1 is Z=66 ohm at 10KHz. This impedance is = 66 ohm = 34 ohm + j 540uH.\u003c\/p\u003e\n\u003cp\u003eOutput Relay 1: DPDT, Max. Switching power of 120W; 10uA to 10A; High Dielectric strength coil-contacts: 1,000 VAC;\u003c\/p\u003e\n\u003cp\u003eOpen contacts: 750 VAC; Conforms to FCC Part 68 requirements; Ag + Au clad bifurcated contacts fully sealed.\u003c\/p\u003e\n\u003cp\u003eSystem Requirement: Any Z-Wave™ enabled network and controller.\u003c\/p\u003e\n\u003cp\u003e* FCC and Canada IC certified for 908.4 MHZ Z-Wave™ RF communications.\u003cbr\u003e * Complies with European Test standard: ETSI EN 300 220 for 868.4 MHZ Z-Wave™ RF communications.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"FortrezZ","offers":[{"title":"Default Title","offer_id":17003622470,"sku":"MIMOlite","price":89.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0600\/1521\/products\/MIMOlite_isolated.png?v=1462998289","url":"https:\/\/innovativehomesys.com\/products\/mimolite-z-wave-low-voltage-input-output-module","provider":"Innovative Home Systems","version":"1.0","type":"link"}